Design data:

1. CAPACITY: 200 NM3/hr.

2. PRESSURE: 150 MMWC.

3. FUME HANDLE: EXHAUST GASES.

4. SUCTION TEMPERATURE: As per MOC.

5. STATIC LOAD: @200 Kgs.

6. DYNAMIC LOAD: @325 Kgs.

7. Motor:  HP

Autocad true scale drawing. For more assistant you can mail us on following Email Adress.

This blower already manufactured and commissioning successfully in industry.